diff --git a/content/cumulus-linux-43/Whats-New/rn.md b/content/cumulus-linux-43/Whats-New/rn.md index 1b89e2b9cf..99df511f91 100644 --- a/content/cumulus-linux-43/Whats-New/rn.md +++ b/content/cumulus-linux-43/Whats-New/rn.md @@ -65,7 +65,7 @@ pdfhidden: True | [2782033](#2782033)
| The following vulnerabilities have been announced in the openssl packages:CVE-2021-3711: buffer overflow vulnerability in SM2 decryption
CVE-2021-3712: buffer overrun when processing ASN.1 strings in the X509_aux_print() function
More details at https://www.openssl.org/news/secadv/20210824.txt
Vulnerable: <= 1.1.1d-0+deb10u6Fixed: 1.1.1d-0+deb10u7 | 4.0.0-4.4.1 | 4.4.2-4.4.5| | [2781537](#2781537)
| In Cumulus VX, the iptables FORWARD chain does not count hits. To work around this issue, use -t mangle -A PREROUTING instead of FORWARD. | 4.3.0-4.4.5 | 5.0.0-5.6.0| | [2771871](#2771871)
| IPv4 and IPv6 neighbor entries in a FAILED state are incorrectly programmed into hardware as FORWARD entries instead of TRAP entries. Traffic is forwarded to these neighbors with a destination MAC address of 00:00:00:00:00:00 instead of trapping them to the CPU to resolve the correct MAC address
This affects failed neighbor entries on routed interfaces that are not SVIs. | 4.3.0-4.4.1 | 4.4.2-4.4.5| -| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. | 4.3.0-4.4.5 | | +| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. | 4.3.0-4.4.5 | | | [2754791](#2754791)
| Remote MAC addreses in zebra are out of sync with bgpd. The zebra MAC addresses point to an incorrect (old) VTEP IP address and the sequence number is one higher than in BGP. | 3.7.14.2-3.7.16, 4.3.0-4.4.5 | | | [2754691](#2754691)
| CVE-2021-3672: in c-ares, a library that performs DNS requests and name resolution asynchronously, missing input validation of hostnames returned by DNS servers can lead to output of wrong hostnames (leading to Domain Hijacking)
Vulnerable: 1.14.0-1Fixed: 1.14.0-1+deb10u1 | 4.0.0-4.4.1 | 4.4.2-4.4.5| | [2754685](#2754685)
| CVE-2021-38165: lynx, a non-graphical (text-mode) web browser, does not properly handle the userinfo subcomponent of a URI, which can lead to leaking of credential in cleartext in SNI data
Vulnerable: 2.8.9rel.1-3Fixed: 2.8.9rel.1-3+deb10u1 | 4.0.0-4.4.1 | 4.4.2-4.4.5| @@ -394,7 +394,7 @@ pdfhidden: True | [2782033](#2782033)
| The following vulnerabilities have been announced in the openssl packages:CVE-2021-3711: buffer overflow vulnerability in SM2 decryption
CVE-2021-3712: buffer overrun when processing ASN.1 strings in the X509_aux_print() function
More details at https://www.openssl.org/news/secadv/20210824.txt
Vulnerable: <= 1.1.1d-0+deb10u6Fixed: 1.1.1d-0+deb10u7 | 4.0.0-4.4.1 | 4.4.2-4.4.5| | [2781537](#2781537)
| In Cumulus VX, the iptables FORWARD chain does not count hits. To work around this issue, use -t mangle -A PREROUTING instead of FORWARD. | 4.3.0-4.4.5 | 5.0.0-5.6.0| | [2771871](#2771871)
| IPv4 and IPv6 neighbor entries in a FAILED state are incorrectly programmed into hardware as FORWARD entries instead of TRAP entries. Traffic is forwarded to these neighbors with a destination MAC address of 00:00:00:00:00:00 instead of trapping them to the CPU to resolve the correct MAC address
This affects failed neighbor entries on routed interfaces that are not SVIs. | 4.3.0-4.4.1 | 4.4.2-4.4.5| -| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. | 4.3.0-4.4.5 | | +| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. | 4.3.0-4.4.5 | | | [2754791](#2754791)
| Remote MAC addreses in zebra are out of sync with bgpd. The zebra MAC addresses point to an incorrect (old) VTEP IP address and the sequence number is one higher than in BGP. | 3.7.14.2-3.7.16, 4.3.0-4.4.5 | | | [2754691](#2754691)
| CVE-2021-3672: in c-ares, a library that performs DNS requests and name resolution asynchronously, missing input validation of hostnames returned by DNS servers can lead to output of wrong hostnames (leading to Domain Hijacking)
Vulnerable: 1.14.0-1Fixed: 1.14.0-1+deb10u1 | 4.0.0-4.4.1 | 4.4.2-4.4.5| | [2754685](#2754685)
| CVE-2021-38165: lynx, a non-graphical (text-mode) web browser, does not properly handle the userinfo subcomponent of a URI, which can lead to leaking of credential in cleartext in SNI data
Vulnerable: 2.8.9rel.1-3Fixed: 2.8.9rel.1-3+deb10u1 | 4.0.0-4.4.1 | 4.4.2-4.4.5| diff --git a/content/cumulus-linux-43/rn.xml b/content/cumulus-linux-43/rn.xml index 92b9262385..1ed1b1adb8 100644 --- a/content/cumulus-linux-43/rn.xml +++ b/content/cumulus-linux-43/rn.xml @@ -351,7 +351,7 @@ This affects failed neighbor entries on routed interfaces that are not SVIs. 2771653 -When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. +When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. 4.3.0-4.4.5 @@ -2777,7 +2777,7 @@ This affects failed neighbor entries on routed interfaces that are not SVIs. 2771653 -When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. +When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. 4.3.0-4.4.5 diff --git a/content/cumulus-linux-44/Whats-New/rn.md b/content/cumulus-linux-44/Whats-New/rn.md index 7f7edd66e6..44ed2ee0a0 100644 --- a/content/cumulus-linux-44/Whats-New/rn.md +++ b/content/cumulus-linux-44/Whats-New/rn.md @@ -116,7 +116,7 @@ pdfhidden: True | [2780915](#2780915)
| In NVUE, you can't deactivate the IPv4 address family per neighbor. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780834](#2780834)
| To enable an address family on a peer, you have to enable the address family globally. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780211](#2780211)
| When you use the NVUE nv set vrf default router bgp peer local-as asn command to configure a local AS, Cumulus Linux does not update the etc/frr/frr.conf file. | 4.4.0-4.4.5 | 5.0.0-5.6.0| -| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. | 4.3.0-4.4.5 | | +| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. | 4.3.0-4.4.5 | | | [2763819](#2763819)
| When you enable LACP bypass on a bond, traffic to static MAC addresses configured on the bond might not work when LACP bypass is enforced. | 4.4.0-4.4.5 | | | [2754791](#2754791)
| Remote MAC addreses in zebra are out of sync with bgpd. The zebra MAC addresses point to an incorrect (old) VTEP IP address and the sequence number is one higher than in BGP. | 3.7.14.2-3.7.16, 4.3.0-4.4.5 | | | [2753955](#2753955)
| On the Lenovo MSN3700 switch, if you try to configure an interface with a link speed of 200G, the configuration fails. | 4.2.1-4.4.5 | 5.0.0-5.6.0| @@ -407,7 +407,7 @@ pdfhidden: True | [2780915](#2780915)
| In NVUE, you can't deactivate the IPv4 address family per neighbor. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780834](#2780834)
| To enable an address family on a peer, you have to enable the address family globally. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780211](#2780211)
| When you use the NVUE nv set vrf default router bgp peer local-as asn command to configure a local AS, Cumulus Linux does not update the etc/frr/frr.conf file. | 4.4.0-4.4.5 | 5.0.0-5.6.0| -| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. | 4.3.0-4.4.5 | | +| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. | 4.3.0-4.4.5 | | | [2763819](#2763819)
| When you enable LACP bypass on a bond, traffic to static MAC addresses configured on the bond might not work when LACP bypass is enforced. | 4.4.0-4.4.5 | | | [2754791](#2754791)
| Remote MAC addreses in zebra are out of sync with bgpd. The zebra MAC addresses point to an incorrect (old) VTEP IP address and the sequence number is one higher than in BGP. | 3.7.14.2-3.7.16, 4.3.0-4.4.5 | | | [2753955](#2753955)
| On the Lenovo MSN3700 switch, if you try to configure an interface with a link speed of 200G, the configuration fails. | 4.2.1-4.4.5 | 5.0.0-5.6.0| @@ -733,7 +733,7 @@ pdfhidden: True | [2780915](#2780915)
| In NVUE, you can't deactivate the IPv4 address family per neighbor. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780834](#2780834)
| To enable an address family on a peer, you have to enable the address family globally. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780211](#2780211)
| When you use the NVUE nv set vrf default router bgp peer local-as asn command to configure a local AS, Cumulus Linux does not update the etc/frr/frr.conf file. | 4.4.0-4.4.5 | 5.0.0-5.6.0| -| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. | 4.3.0-4.4.5 | | +| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. | 4.3.0-4.4.5 | | | [2763819](#2763819)
| When you enable LACP bypass on a bond, traffic to static MAC addresses configured on the bond might not work when LACP bypass is enforced. | 4.4.0-4.4.5 | | | [2754791](#2754791)
| Remote MAC addreses in zebra are out of sync with bgpd. The zebra MAC addresses point to an incorrect (old) VTEP IP address and the sequence number is one higher than in BGP. | 3.7.14.2-3.7.16, 4.3.0-4.4.5 | | | [2753955](#2753955)
| On the Lenovo MSN3700 switch, if you try to configure an interface with a link speed of 200G, the configuration fails. | 4.2.1-4.4.5 | 5.0.0-5.6.0| @@ -1038,7 +1038,7 @@ pdfhidden: True | [2780915](#2780915)
| In NVUE, you can't deactivate the IPv4 address family per neighbor. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780834](#2780834)
| To enable an address family on a peer, you have to enable the address family globally. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780211](#2780211)
| When you use the NVUE nv set vrf default router bgp peer local-as asn command to configure a local AS, Cumulus Linux does not update the etc/frr/frr.conf file. | 4.4.0-4.4.5 | 5.0.0-5.6.0| -| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. | 4.3.0-4.4.5 | | +| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. | 4.3.0-4.4.5 | | | [2763819](#2763819)
| When you enable LACP bypass on a bond, traffic to static MAC addresses configured on the bond might not work when LACP bypass is enforced. | 4.4.0-4.4.5 | | | [2754791](#2754791)
| Remote MAC addreses in zebra are out of sync with bgpd. The zebra MAC addresses point to an incorrect (old) VTEP IP address and the sequence number is one higher than in BGP. | 3.7.14.2-3.7.16, 4.3.0-4.4.5 | | | [2753955](#2753955)
| On the Lenovo MSN3700 switch, if you try to configure an interface with a link speed of 200G, the configuration fails. | 4.2.1-4.4.5 | 5.0.0-5.6.0| @@ -1365,7 +1365,7 @@ pdfhidden: True | [2780834](#2780834)
| To enable an address family on a peer, you have to enable the address family globally. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2780211](#2780211)
| When you use the NVUE nv set vrf default router bgp peer local-as asn command to configure a local AS, Cumulus Linux does not update the etc/frr/frr.conf file. | 4.4.0-4.4.5 | 5.0.0-5.6.0| | [2771871](#2771871)
| IPv4 and IPv6 neighbor entries in a FAILED state are incorrectly programmed into hardware as FORWARD entries instead of TRAP entries. Traffic is forwarded to these neighbors with a destination MAC address of 00:00:00:00:00:00 instead of trapping them to the CPU to resolve the correct MAC address
This affects failed neighbor entries on routed interfaces that are not SVIs. | 4.3.0-4.4.1 | 4.4.2-4.4.5| -| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. | 4.3.0-4.4.5 | | +| [2771653](#2771653)
| When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. | 4.3.0-4.4.5 | | | [2763819](#2763819)
| When you enable LACP bypass on a bond, traffic to static MAC addresses configured on the bond might not work when LACP bypass is enforced. | 4.4.0-4.4.5 | | | [2755614](#2755614)
| When route_preferred_over_neigh is set to FALSE in the /etc/cumulus/switchd.conf file, host routes (/32 or /128) are used for forwarding in hardware instead of a local neighbor entry. | 4.0.0-4.3.0, 4.4.0-4.4.5 | 4.3.1, 5.0.0-5.6.0| | [2754791](#2754791)
| Remote MAC addreses in zebra are out of sync with bgpd. The zebra MAC addresses point to an incorrect (old) VTEP IP address and the sequence number is one higher than in BGP. | 3.7.14.2-3.7.16, 4.3.0-4.4.5 | | diff --git a/content/cumulus-linux-44/rn.xml b/content/cumulus-linux-44/rn.xml index 4783d287b1..789a667378 100644 --- a/content/cumulus-linux-44/rn.xml +++ b/content/cumulus-linux-44/rn.xml @@ -706,7 +706,7 @@ To work around this issue, do not disable EVPN Advertise Primary IP Address, whi 2771653 -When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. +When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. 4.3.0-4.4.5 @@ -2801,7 +2801,7 @@ To work around this issue, do not disable EVPN Advertise Primary IP Address, whi 2771653 -When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. +When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. 4.3.0-4.4.5 @@ -5092,7 +5092,7 @@ To work around this issue, do not disable EVPN Advertise Primary IP Address, whi 2771653 -When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. +When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. 4.3.0-4.4.5 @@ -7276,7 +7276,7 @@ To work around this issue, do not disable EVPN Advertise Primary IP Address, whi 2771653 -When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. +When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. 4.3.0-4.4.5 @@ -9654,7 +9654,7 @@ This affects failed neighbor entries on routed interfaces that are not SVIs. 2771653 -When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more which consumes a lot of hardware space. +When using W-ECMP, the weights for various BGP next hops can sometimes be in the range of 100s or more, which consumes a lot of hardware space. 4.3.0-4.4.5 diff --git a/content/cumulus-linux-51/Whats-New/rn.md b/content/cumulus-linux-51/Whats-New/rn.md index b82700e44e..11f1d5783e 100644 --- a/content/cumulus-linux-51/Whats-New/rn.md +++ b/content/cumulus-linux-51/Whats-New/rn.md @@ -32,7 +32,7 @@ pdfhidden: True | [3388067](#3388067)
| TACACS+ packages in the local apt repository might be out of date; as a result, the upgrade does not install tacacs0 through tacacs15 users in the correct NVUE groups. When you run NVUE commands as a TACACS+ user, the commands fail and you see the error You do not have permission to execute that command
To obtain the correct packages, install the tacplus-client package and its dependencies from apt.cumulusnetworks.com. | 5.1.0-5.4.0 | 5.5.0-5.6.0| | [3351951](#3351951)
None | Currently, the default core dump size limit on Cumulus Linux is 256M but the SDK generates core dumps around 800M. To avoid incomplete core files, you can increase the core dump size limit. | 4.2.1-4.3.1, 4.4.0-5.3.1 | 4.3.2, 5.4.0-5.6.0| | [3350789](#3350789)
| NVUE deprecated the port split command options (2x10G, 2x25G, 2x40G, 2x50G, 2x100G, 2x200G, 4x10G, 4x25G, 4x50G, 4x100G, 8x50G) with no backwards compatibility. | 5.0.0-5.4.0 | 5.5.0-5.6.0| -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3330705](#3330705)
| When using TACACS+, a TACACS+ server name that returns more than one IP address, such as an IPv6 and IPv4 address, is counted many times against the limit of seven TACACS+ servers, which might cause some of the later listed servers to be ignored as over the limit. To work around this issue, you can set the prefer_ip_version configuration option (the default value is 4) to choose between an IPv4 or IPv6 address if both are present. | 3.7.0-5.3.1 | 5.4.0-5.6.0| | [3327477](#3327477)
| If you use su to change to a user specified through TACACS+, the user becomes the local tacacs0 thru tacacs15 user instead of the named user to run sudo commands. As a result, the named user password might not match the local tacacs0 thru tacacs15 user password. | 3.7.0-3.7.16, 4.0.0-4.4.5, 5.0.0-5.6.0 | | | [3301988](#3301988)
| Some EVPN multihoming show commands might cause BGP to crash if you use the json flag and attempt to reference the default VRF by name. For example, show bgp l2vpn evpn es-vrf json. | 5.0.0-5.3.1 | 5.4.0-5.6.0| diff --git a/content/cumulus-linux-51/rn.xml b/content/cumulus-linux-51/rn.xml index 41daa7a89a..c06735ba73 100644 --- a/content/cumulus-linux-51/rn.xml +++ b/content/cumulus-linux-51/rn.xml @@ -127,9 +127,7 @@ To obtain the correct packages, install the {{tacplus-client}} package and its d 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 diff --git a/content/cumulus-linux-52/Whats-New/rn.md b/content/cumulus-linux-52/Whats-New/rn.md index 404d90c0a0..0af7014537 100644 --- a/content/cumulus-linux-52/Whats-New/rn.md +++ b/content/cumulus-linux-52/Whats-New/rn.md @@ -38,7 +38,7 @@ pdfhidden: True | [3351936](#3351936)
| Switch fans run at very high speed but the temperature is normal. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3350789](#3350789)
| NVUE deprecated the port split command options (2x10G, 2x25G, 2x40G, 2x50G, 2x100G, 2x200G, 4x10G, 4x25G, 4x50G, 4x100G, 8x50G) with no backwards compatibility. | 5.0.0-5.4.0 | 5.5.0-5.6.0| | [3349207](#3349207)
| The switch does not learn MAC addresses from DHCP packets. When a DHCP enabled host is plugged in for the first time, it tries to obtain an IP address through DHCP. The switch does not learn the MAC address of the host when it receives these DHCP packets; therefore, the host MAC address is not updated in the local forwarding database and it does not get advertised across EVPN. The switch learns the MAC address when it receives other packets, such as ARP or ND from the host. To work around this issue, either configure a temporary IP address on the host to initiate ARP/ND or enable IPv6, which sends ND after link local address creation. | 5.2.0-5.4.0 | 5.5.0-5.6.0| -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3339336](#3339336)
| The ethtool -m command does not show Digital Optical Monitoring (DOM) for SFP transceivers. To work around this issue, run the l1-show or mlxlink command instead. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3334275](#3334275)
| The sensors.conf files in Cumulus Linux are out of date. | 5.2.0-5.6.0 | | | [3330705](#3330705)
| When using TACACS+, a TACACS+ server name that returns more than one IP address, such as an IPv6 and IPv4 address, is counted many times against the limit of seven TACACS+ servers, which might cause some of the later listed servers to be ignored as over the limit. To work around this issue, you can set the prefer_ip_version configuration option (the default value is 4) to choose between an IPv4 or IPv6 address if both are present. | 3.7.0-5.3.1 | 5.4.0-5.6.0| @@ -60,7 +60,7 @@ pdfhidden: True | [3227677](#3227677)
| When daylight saving time changes the time, the MLAG initDelay timer resets and all MLAG bonds go down. | 4.4.4-5.2.1 | 5.3.0-5.6.0| | [3227651](#3227651)
None | Docker commands can cause Cumulus Linux commands to fail. apt upgrade can also fail if you use Docker commands implicitly. To work around this issue, run ulimit -v unlimited before running Docker commands or running apt upgrade. | 5.2.0-5.2.1 | 5.3.0-5.6.0| | [3226525](#3226525)
| When using TACACS+, if you configure per-command authorization with the tacplus-restrict command, NVUE configuration commands fail for any user with a privilege level lower than 15. This occurs because NVUE is not able to create a .local user directory. | 5.2.0-5.3.1 | 5.4.0-5.6.0| -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3218207](#3218207)
None | Certain routes on tenant VRFs have missing next hop entries because the router MAC address is missing in the bridge forwarding database table that corresponds to the remote VTEP. As a result, traffic forwarding is affected for these routes. | 4.3.0-5.2.1 | 5.3.0-5.6.0| | [3217675](#3217675)
| When you run the NVUE nv set bridge domain br_default multicast snooping enable off command to disable multicast snooping, the bridge still shows that multicast snooping is enabled. | 5.0.1-5.2.1 | 5.3.0-5.6.0| | [3217674](#3217674)
| Multicast PTP over UDP traffic does not forward to data ports when the PTP service is disabled. To work around this issue, change the ptp.timestamping setting to FALSE in the /etc/cumulus/switchd.conf file, then restart switchd. | 5.0.1-5.2.1 | 5.3.0-5.6.0| @@ -171,7 +171,7 @@ pdfhidden: True | [3351936](#3351936)
| Switch fans run at very high speed but the temperature is normal. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3350789](#3350789)
| NVUE deprecated the port split command options (2x10G, 2x25G, 2x40G, 2x50G, 2x100G, 2x200G, 4x10G, 4x25G, 4x50G, 4x100G, 8x50G) with no backwards compatibility. | 5.0.0-5.4.0 | 5.5.0-5.6.0| | [3349207](#3349207)
| The switch does not learn MAC addresses from DHCP packets. When a DHCP enabled host is plugged in for the first time, it tries to obtain an IP address through DHCP. The switch does not learn the MAC address of the host when it receives these DHCP packets; therefore, the host MAC address is not updated in the local forwarding database and it does not get advertised across EVPN. The switch learns the MAC address when it receives other packets, such as ARP or ND from the host. To work around this issue, either configure a temporary IP address on the host to initiate ARP/ND or enable IPv6, which sends ND after link local address creation. | 5.2.0-5.4.0 | 5.5.0-5.6.0| -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3339336](#3339336)
| The ethtool -m command does not show Digital Optical Monitoring (DOM) for SFP transceivers. To work around this issue, run the l1-show or mlxlink command instead. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3334275](#3334275)
| The sensors.conf files in Cumulus Linux are out of date. | 5.2.0-5.6.0 | | | [3330705](#3330705)
| When using TACACS+, a TACACS+ server name that returns more than one IP address, such as an IPv6 and IPv4 address, is counted many times against the limit of seven TACACS+ servers, which might cause some of the later listed servers to be ignored as over the limit. To work around this issue, you can set the prefer_ip_version configuration option (the default value is 4) to choose between an IPv4 or IPv6 address if both are present. | 3.7.0-5.3.1 | 5.4.0-5.6.0| @@ -194,7 +194,7 @@ pdfhidden: True | [3227677](#3227677)
| When daylight saving time changes the time, the MLAG initDelay timer resets and all MLAG bonds go down. | 4.4.4-5.2.1 | 5.3.0-5.6.0| | [3227651](#3227651)
None | Docker commands can cause Cumulus Linux commands to fail. apt upgrade can also fail if you use Docker commands implicitly. To work around this issue, run ulimit -v unlimited before running Docker commands or running apt upgrade. | 5.2.0-5.2.1 | 5.3.0-5.6.0| | [3226525](#3226525)
| When using TACACS+, if you configure per-command authorization with the tacplus-restrict command, NVUE configuration commands fail for any user with a privilege level lower than 15. This occurs because NVUE is not able to create a .local user directory. | 5.2.0-5.3.1 | 5.4.0-5.6.0| -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3218207](#3218207)
None | Certain routes on tenant VRFs have missing next hop entries because the router MAC address is missing in the bridge forwarding database table that corresponds to the remote VTEP. As a result, traffic forwarding is affected for these routes. | 4.3.0-5.2.1 | 5.3.0-5.6.0| | [3217675](#3217675)
| When you run the NVUE nv set bridge domain br_default multicast snooping enable off command to disable multicast snooping, the bridge still shows that multicast snooping is enabled. | 5.0.1-5.2.1 | 5.3.0-5.6.0| | [3217674](#3217674)
| Multicast PTP over UDP traffic does not forward to data ports when the PTP service is disabled. To work around this issue, change the ptp.timestamping setting to FALSE in the /etc/cumulus/switchd.conf file, then restart switchd. | 5.0.1-5.2.1 | 5.3.0-5.6.0| diff --git a/content/cumulus-linux-52/rn.xml b/content/cumulus-linux-52/rn.xml index 2ed5df0357..077d154477 100644 --- a/content/cumulus-linux-52/rn.xml +++ b/content/cumulus-linux-52/rn.xml @@ -163,9 +163,7 @@ To obtain the correct packages, install the {{tacplus-client}} package and its d 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -307,7 +305,7 @@ ethtool (-S): unknown parameter 'clear' 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0 @@ -1009,9 +1007,7 @@ To obtain the correct packages, install the {{tacplus-client}} package and its d 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -1159,7 +1155,7 @@ ethtool (-S): unknown parameter 'clear' 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0 diff --git a/content/cumulus-linux-53/Whats-New/rn.md b/content/cumulus-linux-53/Whats-New/rn.md index d91da49a53..e8f24f9070 100644 --- a/content/cumulus-linux-53/Whats-New/rn.md +++ b/content/cumulus-linux-53/Whats-New/rn.md @@ -56,7 +56,7 @@ pdfhidden: True | [3351936](#3351936)
| Switch fans run at very high speed but the temperature is normal. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3350789](#3350789)
| NVUE deprecated the port split command options (2x10G, 2x25G, 2x40G, 2x50G, 2x100G, 2x200G, 4x10G, 4x25G, 4x50G, 4x100G, 8x50G) with no backwards compatibility. | 5.0.0-5.4.0 | 5.5.0-5.6.0| | [3349207](#3349207)
| The switch does not learn MAC addresses from DHCP packets. When a DHCP enabled host is plugged in for the first time, it tries to obtain an IP address through DHCP. The switch does not learn the MAC address of the host when it receives these DHCP packets; therefore, the host MAC address is not updated in the local forwarding database and it does not get advertised across EVPN. The switch learns the MAC address when it receives other packets, such as ARP or ND from the host. To work around this issue, either configure a temporary IP address on the host to initiate ARP/ND or enable IPv6, which sends ND after link local address creation. | 5.2.0-5.4.0 | 5.5.0-5.6.0| -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3340890](#3340890)
| When you run the NVUE nv show interface command, you see an error similar to the following:
Error: GET /nvue_v1/interface/swp45?rev=operational responded with 500 INTERNAL SERVER ERROR
| 5.3.0-5.4.0 | 5.5.0-5.6.0| | [3339336](#3339336)
| The ethtool -m command does not show Digital Optical Monitoring (DOM) for SFP transceivers. To work around this issue, run the l1-show or mlxlink command instead. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3334275](#3334275)
| The sensors.conf files in Cumulus Linux are out of date. | 5.2.0-5.6.0 | | @@ -89,7 +89,7 @@ pdfhidden: True | [3234814](#3234814)
| With double tagged QinQ interfaces, if the bridge corresponding to the QinQ interface flaps, you might see invalid learning notifications and errors from similar to the following:
Can't set non-static MAC address for non-vPort 0x0001006B when VID is VFID. 
| 5.3.0-5.4.0 | 5.5.0-5.6.0| | [3226525](#3226525)
| When using TACACS+, if you configure per-command authorization with the tacplus-restrict command, NVUE configuration commands fail for any user with a privilege level lower than 15. This occurs because NVUE is not able to create a .local user directory. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3226506](#3226506)
| The l1-show eth0 command does not show port information and is not supported in this release. | 5.3.0-5.6.0 | | -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3187469](#3187469)
| At high scale with 160 VRFs and 10 VLANs per VRF (a total of 1600 VLANs), you see traffic loss during primary switch reboot. To work around this issue, reduce the scale to 40 VRFs with no more than 400 VLANs in the configuration, and use a common MAC address. | 5.1.0-5.5.1 | 5.6.0| | [3178090](#3178090)
| The cl-support generation script causes TC filter collection to run as a background process for each interface, which can lead to memory exhaustion on a high scale configuration and on a switch with a small memory footprint. | 5.1.0-5.5.1 | 5.6.0| | [3172682](#3172682)
| On rare occasions, when you query the system hostname through the hostnamctl application, you see a timeout. NVUE uses the hostnamctl application to determine the system hostname, which can result in an nv config apply command failure. | 5.2.0-5.5.1 | 5.6.0| @@ -175,7 +175,7 @@ pdfhidden: True | [3351936](#3351936)
| Switch fans run at very high speed but the temperature is normal. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3350789](#3350789)
| NVUE deprecated the port split command options (2x10G, 2x25G, 2x40G, 2x50G, 2x100G, 2x200G, 4x10G, 4x25G, 4x50G, 4x100G, 8x50G) with no backwards compatibility. | 5.0.0-5.4.0 | 5.5.0-5.6.0| | [3349207](#3349207)
| The switch does not learn MAC addresses from DHCP packets. When a DHCP enabled host is plugged in for the first time, it tries to obtain an IP address through DHCP. The switch does not learn the MAC address of the host when it receives these DHCP packets; therefore, the host MAC address is not updated in the local forwarding database and it does not get advertised across EVPN. The switch learns the MAC address when it receives other packets, such as ARP or ND from the host. To work around this issue, either configure a temporary IP address on the host to initiate ARP/ND or enable IPv6, which sends ND after link local address creation. | 5.2.0-5.4.0 | 5.5.0-5.6.0| -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3340890](#3340890)
| When you run the NVUE nv show interface command, you see an error similar to the following:
Error: GET /nvue_v1/interface/swp45?rev=operational responded with 500 INTERNAL SERVER ERROR
| 5.3.0-5.4.0 | 5.5.0-5.6.0| | [3339336](#3339336)
| The ethtool -m command does not show Digital Optical Monitoring (DOM) for SFP transceivers. To work around this issue, run the l1-show or mlxlink command instead. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3334275](#3334275)
| The sensors.conf files in Cumulus Linux are out of date. | 5.2.0-5.6.0 | | @@ -209,7 +209,7 @@ pdfhidden: True | [3234814](#3234814)
| With double tagged QinQ interfaces, if the bridge corresponding to the QinQ interface flaps, you might see invalid learning notifications and errors from similar to the following:
Can't set non-static MAC address for non-vPort 0x0001006B when VID is VFID. 
| 5.3.0-5.4.0 | 5.5.0-5.6.0| | [3226525](#3226525)
| When using TACACS+, if you configure per-command authorization with the tacplus-restrict command, NVUE configuration commands fail for any user with a privilege level lower than 15. This occurs because NVUE is not able to create a .local user directory. | 5.2.0-5.3.1 | 5.4.0-5.6.0| | [3226506](#3226506)
| The l1-show eth0 command does not show port information and is not supported in this release. | 5.3.0-5.6.0 | | -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3187469](#3187469)
| At high scale with 160 VRFs and 10 VLANs per VRF (a total of 1600 VLANs), you see traffic loss during primary switch reboot. To work around this issue, reduce the scale to 40 VRFs with no more than 400 VLANs in the configuration, and use a common MAC address. | 5.1.0-5.5.1 | 5.6.0| | [3178090](#3178090)
| The cl-support generation script causes TC filter collection to run as a background process for each interface, which can lead to memory exhaustion on a high scale configuration and on a switch with a small memory footprint. | 5.1.0-5.5.1 | 5.6.0| | [3172682](#3172682)
| On rare occasions, when you query the system hostname through the hostnamctl application, you see a timeout. NVUE uses the hostnamctl application to determine the system hostname, which can result in an nv config apply command failure. | 5.2.0-5.5.1 | 5.6.0| diff --git a/content/cumulus-linux-53/rn.xml b/content/cumulus-linux-53/rn.xml index d5024ad972..cafd8b804a 100644 --- a/content/cumulus-linux-53/rn.xml +++ b/content/cumulus-linux-53/rn.xml @@ -282,9 +282,7 @@ To obtain the correct packages, install the {{tacplus-client}} package and its d 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -502,7 +500,7 @@ Can't set non-static MAC address for non-vPort 0x0001006B when VID is VFID. 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0 @@ -1017,9 +1015,7 @@ To obtain the correct packages, install the {{tacplus-client}} package and its d 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -1246,7 +1242,7 @@ Can't set non-static MAC address for non-vPort 0x0001006B when VID is VFID. 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0 diff --git a/content/cumulus-linux-54/Whats-New/rn.md b/content/cumulus-linux-54/Whats-New/rn.md index dabef30624..da7a39d3e9 100644 --- a/content/cumulus-linux-54/Whats-New/rn.md +++ b/content/cumulus-linux-54/Whats-New/rn.md @@ -80,7 +80,7 @@ pdfhidden: True | [3350027](#3350027)
| If you uninstall dynamic NAT rules and switchd restarts before all the dynamic NAT flows age out and are deleted, you might see dynamic flow deletion errors in switchd.log. These errors do not affect new dynamic NAT flows from new NAT rules. | 5.4.0-5.6.0 | | | [3349533](#3349533)
| On the Spectrum-2 and Spectrum-3 switch with ports operating at 1G speed, there is loss of frames that have an odd or random frame size. In the frame size range of 75 to 1000 bytes, there is frame loss of less than approximately one percent for all odd or random frame sizes in the range. In the frame size range greater than 1000 bytes, there is no loss observed. | 5.4.0 | 5.5.0-5.6.0| | [3349207](#3349207)
| The switch does not learn MAC addresses from DHCP packets. When a DHCP enabled host is plugged in for the first time, it tries to obtain an IP address through DHCP. The switch does not learn the MAC address of the host when it receives these DHCP packets; therefore, the host MAC address is not updated in the local forwarding database and it does not get advertised across EVPN. The switch learns the MAC address when it receives other packets, such as ARP or ND from the host. To work around this issue, either configure a temporary IP address on the host to initiate ARP/ND or enable IPv6, which sends ND after link local address creation. | 5.2.0-5.4.0 | 5.5.0-5.6.0| -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3347538](#3347538)
| When connecting NVIDIA-to-NVIDIA in PAM4, you must enable auto-negotiation. | 5.4.0-5.6.0 | | | [3345054](#3345054)
| The NVUE nv show interface qos command takes a significant time to show output or times out. To work around this issue, use specific QoS commands. For example, to show congestion control information, run the nv show interface qos congestion-control command. | 5.4.0-5.6.0 | | | [3344846](#3344846)
| The Spectrum-3 hardware configuration is not optimized for the best PTP accuracy when using 25GbE. You might see higher than expected PTP offsets on this platforms and interface speed. | 5.4.0-5.5.1 | 5.6.0| @@ -102,7 +102,7 @@ pdfhidden: True | [3234814](#3234814)
| With double tagged QinQ interfaces, if the bridge corresponding to the QinQ interface flaps, you might see invalid learning notifications and errors from similar to the following:
Can't set non-static MAC address for non-vPort 0x0001006B when VID is VFID. 
| 5.3.0-5.4.0 | 5.5.0-5.6.0| | [3232091](#3232091)
| The NVUE nv unset interface link lanes command does not restore the port lane setting to the default value. To work around this issue, run the nv set interface link lanes command. | 5.4.0-5.6.0 | | | [3226506](#3226506)
| The l1-show eth0 command does not show port information and is not supported in this release. | 5.3.0-5.6.0 | | -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3187469](#3187469)
| At high scale with 160 VRFs and 10 VLANs per VRF (a total of 1600 VLANs), you see traffic loss during primary switch reboot. To work around this issue, reduce the scale to 40 VRFs with no more than 400 VLANs in the configuration, and use a common MAC address. | 5.1.0-5.5.1 | 5.6.0| | [3178090](#3178090)
| The cl-support generation script causes TC filter collection to run as a background process for each interface, which can lead to memory exhaustion on a high scale configuration and on a switch with a small memory footprint. | 5.1.0-5.5.1 | 5.6.0| | [3172682](#3172682)
| On rare occasions, when you query the system hostname through the hostnamctl application, you see a timeout. NVUE uses the hostnamctl application to determine the system hostname, which can result in an nv config apply command failure. | 5.2.0-5.5.1 | 5.6.0| diff --git a/content/cumulus-linux-54/rn.xml b/content/cumulus-linux-54/rn.xml index 13be4eb081..cbe3a7c378 100644 --- a/content/cumulus-linux-54/rn.xml +++ b/content/cumulus-linux-54/rn.xml @@ -440,9 +440,7 @@ These errors do not affect new dynamic NAT flows from new NAT rules. 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -592,7 +590,7 @@ Can't set non-static MAC address for non-vPort 0x0001006B when VID is VFID. 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0 diff --git a/content/cumulus-linux-55/Whats-New/rn.md b/content/cumulus-linux-55/Whats-New/rn.md index d35f313c61..2e8356d4a5 100644 --- a/content/cumulus-linux-55/Whats-New/rn.md +++ b/content/cumulus-linux-55/Whats-New/rn.md @@ -20,10 +20,10 @@ pdfhidden: True | [3647426](#3647426)
None | If BGP remote-as is set to an integer and you try to configure the local-as for a BGP instance, you see the following error:
% AS specified for local as is the same as the remote as and this is not allowed
This configuration is not allowed; it is considered to be eBGP and local preference is not advertised. | 5.0.0-5.5.1 | 4.3.2-4.4.5, 5.6.0| | [3630492](#3630492)
| On the NVIDIA SN2201 switch, the ledmgrd -d command output shows the system and PSU LED status as orange when the physical LED is green. | 5.5.1-5.6.0 | | | [3616338](#3616338)
| When you reboot an MLAG switch with 3000 or more VNIs, there might be extended traffic loss during reboot. To work around this issue, configure the clagd service initDelay to 300 seconds with the nv set mlag init-delay 300 command. | 5.5.1-5.6.0 | | -| [3610611](#3610611)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | +| [3610611](#3610611)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | | [3609128](#3609128)
| When you use vi with root or sudo, visual mode is enabled by default due to a missing vimrc configuration file. This makes it difficult to copy and paste into vi. In CL5.7.0, the default configuration now includes set mouse-=a
In addition, the CL5.7.0 default configuration for vi now disables modelines, which can be a security risk. | 5.5.0-5.6.0 | | | [3603237](#3603237)
| If the secondary MLAG peer continuously reboots, you might experience momentary traffic loss. | 5.5.1-5.6.0 | | -| [3599699](#3599699)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | +| [3599699](#3599699)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | | [3597456](#3597456)
| NVUE does not allow you to use the reserved name lo in an interface name. | 5.5.1-5.6.0 | | | [3585467](#3585467)
| NVUE and ip link show traditional bridge VLAN subinterface counts incorrectly. The ingress (Rx) count increments correctly but the egress (Tx) count does not increment. This issues occurs because the hardware does not support transmit counters for a VLAN subinterface; therefore, no statistics from the hardware are updated. Statistics for software forwarded packets show correctly. | 5.0.0-5.6.0 | | | [3582826](#3582826)
| When you enable the FRR SNMP agent (agentx) and configure routing adjacencies with short timers (dead, keepalive, and hold time), the routing adjacencies might go down in certain scenarios; for example when you have frequent or concurrent client SNMP requests, you use custom SNMP MIB extensions, you poll OIDs with large responses, or during high CPU load. To work around this issue, you can increase the routing adjacency timers to accommodate SNMP processing. | 5.5.0-5.6.0 | | @@ -84,7 +84,7 @@ pdfhidden: True | [3368217](#3368217)
None | When daylight saving time changes, the MLAG initDelay timer resets and all MLAG bonds go down. | 4.4.4-4.4.5, 5.2.1-5.6.0 | | | [3362113](#3362113)
| If you restore an NVUE startup.yaml file after upgrade that includes breakout ports with QoS configuration or you run the nv config patch command to update a configuration with a yaml file that includes breakout ports with QoS configuration, the NVUE configuration fails to apply and subsequent attempts to run nv config apply fail with the following message:
cumulus@switch:~$ nv config applyInvalid config [rev_id: 11]
qos config is not supported on following invalid interface: swp1s0. Supported on swp and bond interface types
To work around this issue, run nv unset on the configured QoS settings, then apply the breakout port configuration before you configure QoS. Alternatively, you can remove the QoS configuration from the yaml file and patch it separately after applying the breakout configuration. | 5.4.0-5.6.0 | | | [3350027](#3350027)
| If you uninstall dynamic NAT rules and switchd restarts before all the dynamic NAT flows age out and are deleted, you might see dynamic flow deletion errors in switchd.log. These errors do not affect new dynamic NAT flows from new NAT rules. | 5.4.0-5.6.0 | | -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3347538](#3347538)
| When connecting NVIDIA-to-NVIDIA in PAM4, you must enable auto-negotiation. | 5.4.0-5.6.0 | | | [3345054](#3345054)
| The NVUE nv show interface qos command takes a significant time to show output or times out. To work around this issue, use specific QoS commands. For example, to show congestion control information, run the nv show interface qos congestion-control command. | 5.4.0-5.6.0 | | | [3344846](#3344846)
| The Spectrum-3 hardware configuration is not optimized for the best PTP accuracy when using 25GbE. You might see higher than expected PTP offsets on this platforms and interface speed. | 5.4.0-5.5.1 | 5.6.0| @@ -101,7 +101,7 @@ pdfhidden: True | [3241567](#3241567)
| When you apply switch configuration for the first time on a freshly booted switch, you might see the error message Failed to start Hostname Service when you run the nv config apply command after setting the hostname with nv set system hostname. To work around this issue, run the nv config apply command a second time. | 5.3.0-5.6.0 | | | [3232091](#3232091)
| The NVUE nv unset interface link lanes command does not restore the port lane setting to the default value. To work around this issue, run the nv set interface link lanes command. | 5.4.0-5.6.0 | | | [3226506](#3226506)
| The l1-show eth0 command does not show port information and is not supported in this release. | 5.3.0-5.6.0 | | -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3187469](#3187469)
| At high scale with 160 VRFs and 10 VLANs per VRF (a total of 1600 VLANs), you see traffic loss during primary switch reboot. To work around this issue, reduce the scale to 40 VRFs with no more than 400 VLANs in the configuration, and use a common MAC address. | 5.1.0-5.5.1 | 5.6.0| | [3178090](#3178090)
| The cl-support generation script causes TC filter collection to run as a background process for each interface, which can lead to memory exhaustion on a high scale configuration and on a switch with a small memory footprint. | 5.1.0-5.5.1 | 5.6.0| | [3172682](#3172682)
| On rare occasions, when you query the system hostname through the hostnamctl application, you see a timeout. NVUE uses the hostnamctl application to determine the system hostname, which can result in an nv config apply command failure. | 5.2.0-5.5.1 | 5.6.0| @@ -147,9 +147,9 @@ pdfhidden: True |--- |--- |--- |--- | | [3663182](#3663182)
| Changing non-default BGP timers with NCLU or vtysh commands sets the hold time and keep alive interval to 0 seconds. To work around this issue, restart the FRR service with the sudo systemctl restart frr.service command. | 5.3.1-5.6.0 | | | [3647426](#3647426)
None | If BGP remote-as is set to an integer and you try to configure the local-as for a BGP instance, you see the following error:
% AS specified for local as is the same as the remote as and this is not allowed
This configuration is not allowed; it is considered to be eBGP and local preference is not advertised. | 5.0.0-5.5.1 | 4.3.2-4.4.5, 5.6.0| -| [3610611](#3610611)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | +| [3610611](#3610611)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | | [3609128](#3609128)
| When you use vi with root or sudo, visual mode is enabled by default due to a missing vimrc configuration file. This makes it difficult to copy and paste into vi. In CL5.7.0, the default configuration now includes set mouse-=a
In addition, the CL5.7.0 default configuration for vi now disables modelines, which can be a security risk. | 5.5.0-5.6.0 | | -| [3599699](#3599699)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | +| [3599699](#3599699)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | | [3585467](#3585467)
| NVUE and ip link show traditional bridge VLAN subinterface counts incorrectly. The ingress (Rx) count increments correctly but the egress (Tx) count does not increment. This issues occurs because the hardware does not support transmit counters for a VLAN subinterface; therefore, no statistics from the hardware are updated. Statistics for software forwarded packets show correctly. | 5.0.0-5.6.0 | | | [3582826](#3582826)
| When you enable the FRR SNMP agent (agentx) and configure routing adjacencies with short timers (dead, keepalive, and hold time), the routing adjacencies might go down in certain scenarios; for example when you have frequent or concurrent client SNMP requests, you use custom SNMP MIB extensions, you poll OIDs with large responses, or during high CPU load. To work around this issue, you can increase the routing adjacency timers to accommodate SNMP processing. | 5.5.0-5.6.0 | | | [3580435](#3580435)
| On the NVIDIA SN2410 switch with an Innodisk SSD, you might see the following message in syslog:
smartd[501]: Device: /dev/sda [SAT], CHECK POWER STATUS spins up disk (0x00 -> 0xff)
This is a cosmetic issue and does not affect how the switch operates. To prevent this message from occurring, run the hdparm -S 24 /dev/sda command to change the HD timeout. | 5.3.1-5.6.0 | | @@ -206,7 +206,7 @@ pdfhidden: True | [3368217](#3368217)
None | When daylight saving time changes, the MLAG initDelay timer resets and all MLAG bonds go down. | 4.4.4-4.4.5, 5.2.1-5.6.0 | | | [3362113](#3362113)
| If you restore an NVUE startup.yaml file after upgrade that includes breakout ports with QoS configuration or you run the nv config patch command to update a configuration with a yaml file that includes breakout ports with QoS configuration, the NVUE configuration fails to apply and subsequent attempts to run nv config apply fail with the following message:
cumulus@switch:~$ nv config applyInvalid config [rev_id: 11]
qos config is not supported on following invalid interface: swp1s0. Supported on swp and bond interface types
To work around this issue, run nv unset on the configured QoS settings, then apply the breakout port configuration before you configure QoS. Alternatively, you can remove the QoS configuration from the yaml file and patch it separately after applying the breakout configuration. | 5.4.0-5.6.0 | | | [3350027](#3350027)
| If you uninstall dynamic NAT rules and switchd restarts before all the dynamic NAT flows age out and are deleted, you might see dynamic flow deletion errors in switchd.log. These errors do not affect new dynamic NAT flows from new NAT rules. | 5.4.0-5.6.0 | | -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3347538](#3347538)
| When connecting NVIDIA-to-NVIDIA in PAM4, you must enable auto-negotiation. | 5.4.0-5.6.0 | | | [3345054](#3345054)
| The NVUE nv show interface qos command takes a significant time to show output or times out. To work around this issue, use specific QoS commands. For example, to show congestion control information, run the nv show interface qos congestion-control command. | 5.4.0-5.6.0 | | | [3344846](#3344846)
| The Spectrum-3 hardware configuration is not optimized for the best PTP accuracy when using 25GbE. You might see higher than expected PTP offsets on this platforms and interface speed. | 5.4.0-5.5.1 | 5.6.0| @@ -223,7 +223,7 @@ pdfhidden: True | [3241567](#3241567)
| When you apply switch configuration for the first time on a freshly booted switch, you might see the error message Failed to start Hostname Service when you run the nv config apply command after setting the hostname with nv set system hostname. To work around this issue, run the nv config apply command a second time. | 5.3.0-5.6.0 | | | [3232091](#3232091)
| The NVUE nv unset interface link lanes command does not restore the port lane setting to the default value. To work around this issue, run the nv set interface link lanes command. | 5.4.0-5.6.0 | | | [3226506](#3226506)
| The l1-show eth0 command does not show port information and is not supported in this release. | 5.3.0-5.6.0 | | -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3187469](#3187469)
| At high scale with 160 VRFs and 10 VLANs per VRF (a total of 1600 VLANs), you see traffic loss during primary switch reboot. To work around this issue, reduce the scale to 40 VRFs with no more than 400 VLANs in the configuration, and use a common MAC address. | 5.1.0-5.5.1 | 5.6.0| | [3178090](#3178090)
| The cl-support generation script causes TC filter collection to run as a background process for each interface, which can lead to memory exhaustion on a high scale configuration and on a switch with a small memory footprint. | 5.1.0-5.5.1 | 5.6.0| | [3172682](#3172682)
| On rare occasions, when you query the system hostname through the hostnamctl application, you see a timeout. NVUE uses the hostnamctl application to determine the system hostname, which can result in an nv config apply command failure. | 5.2.0-5.5.1 | 5.6.0| diff --git a/content/cumulus-linux-55/rn.xml b/content/cumulus-linux-55/rn.xml index 9d76eaffcd..8597a3fafa 100644 --- a/content/cumulus-linux-55/rn.xml +++ b/content/cumulus-linux-55/rn.xml @@ -48,7 +48,7 @@ This configuration is not allowed; it is considered to be eBGP and local prefere 3610611 -Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the {{nv unset vrf <vrf> loopback ip address <address>}} command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. +Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf <vrf> loopback ip address command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. 5.5.0-5.6.0 @@ -68,7 +68,7 @@ In addition, the CL5.7.0 default configuration for {{vi}} now disables modelines 3599699 -Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the {{nv unset vrf <vrf> loopback ip address <address>}} command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. +Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf <vrf> loopback ip address <address> command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. 5.5.0-5.6.0 @@ -489,9 +489,7 @@ These errors do not affect new dynamic NAT flows from new NAT rules. 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -593,7 +591,7 @@ In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0 @@ -853,7 +851,7 @@ This configuration is not allowed; it is considered to be eBGP and local prefere 3610611 -Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the {{nv unset vrf <vrf> loopback ip address <address>}} command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. +Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf <vrf> loopback ip address command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. 5.5.0-5.6.0 @@ -867,7 +865,7 @@ In addition, the CL5.7.0 default configuration for {{vi}} now disables modelines 3599699 -Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the {{nv unset vrf <vrf> loopback ip address <address>}} command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. +Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf <vrf> loopback ip address <address> command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. 5.5.0-5.6.0 @@ -1264,9 +1262,7 @@ These errors do not affect new dynamic NAT flows from new NAT rules. 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -1368,7 +1364,7 @@ In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0 diff --git a/content/cumulus-linux-56/Whats-New/rn.md b/content/cumulus-linux-56/Whats-New/rn.md index 98bf79a5b4..b7a4dd1765 100644 --- a/content/cumulus-linux-56/Whats-New/rn.md +++ b/content/cumulus-linux-56/Whats-New/rn.md @@ -18,7 +18,7 @@ pdfhidden: True | [3683166](#3683166)
| A statistics issue in the I2C interface to modules is locked and might cause the switch to hang. | 5.6.0 | | | [3669935](#3669935)
| When you add or delete VXLAN VNI and VLAN interfaces, a memory leak might occur in switchd. | 5.6.0 | | | [3668939](#3668939)
| When you enable MIB 1.3.6.1.4.1.40310.1 in the snmpd.conf file, you might see high CPU usage by the snmpd service. | 5.5.1-5.6.0 | | -| [3668809](#3668809)
| SN2410 switches manufactured or sold by OEMs (not Mellanox) might contain fans that do not support system fan direction detection. As a result, the following messages occur in the log:/usr/sbin/smond : : Path /run/hw-management/thermal/fan1_dir does not exist/usr/sbin/smond : : Path /run/hw-management/thermal/fan2_dir does not existsmond has been modified to determine dynamically (at run-time) if the fan has the capability or not
To drop the messages before they get to the log, create a file, such as /etc/rsyslog.d/18-drop_fan_dir_msgs.conf with the following contents, then restart rsyslogd with the systemctl restart rsyslog command
# The lines below cause the offending message to be dropped from all logs:msg, ereregex, ".*Path /run/hw-management/thermal/fan[1-8]_dir does not exist" stop | 5.6.0 | | +| [3668809](#3668809)
| SN2410 switches manufactured or sold by OEMs (not Mellanox) might contain fans that do not support system fan direction detection. As a result, the following messages occur in the log:/usr/sbin/smond : : Path /run/hw-management/thermal/fan1_dir does not exist/usr/sbin/smond : : Path /run/hw-management/thermal/fan2_dir does not existsmond has been modified to determine dynamically (at run-time) if the fan has the capability. To drop the messages before they get to the log, create a file, such as /etc/rsyslog.d/18-drop_fan_dir_msgs.conf with the following contents, then restart rsyslogd with the systemctl restart rsyslog command
# The lines below cause the offending message to be dropped from all logs:msg, ereregex, ".*Path /run/hw-management/thermal/fan[1-8]_dir does not exist" stop | 5.6.0 | | | [3664986](#3664986)
| If a core file is generated with a space in the name, Cumulus Linux generates cl-support files until the file is removed. To work around this issue, rename the core file without the space character. The next cl-support file generated will be moved into the cl-support archive and removed from the filesystem. | 5.6.0 | | | [3663182](#3663182)
| Changing non-default BGP timers with NCLU or vtysh commands sets the hold time and keep alive interval to 0 seconds. To work around this issue, restart the FRR service with the sudo systemctl restart frr.service command. | 5.3.1-5.6.0 | | | [3662354](#3662354)
| When you enable the FRR SNMP agent (agentx) and configure routing adjacencies with short timers (dead, keepalive, and hold time), the routing adjacencies might go down in certain scenarios; for example when you have frequent or concurrent client SNMP requests, you use custom SNMP MIB extensions, you poll OIDs with large responses, or during high CPU load. To work around this issue, you can increase the routing adjacency timers to accommodate SNMP processing. | 5.6.0 | | @@ -32,12 +32,12 @@ pdfhidden: True | [3616338](#3616338)
| When you reboot an MLAG switch with 3000 or more VNIs, there might be extended traffic loss during reboot. To work around this issue, configure the clagd service initDelay to 300 seconds with the nv set mlag init-delay 300 command. | 5.5.1-5.6.0 | | | [3612959](#3612959)
| The interface name for a VLAN subinterface does not show correctly; the VLAN is appended to the interface again. | 5.6.0 | | | [3611215](#3611215)
| In an EVPN multihoming configuration, the switchd service produces error messages similar to the following:
2023-09-07T15:45:56.055477+02:00 switch1 switchd7903: hal_mlx_flx_acl.c:2388 hal_mlx_flx_region_pull_bulk_counters failed
These error messages do not affect how the switch functions; however the messages fill up the switchd logs, which is not desirable. | 5.6.0 | | -| [3610611](#3610611)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | +| [3610611](#3610611)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | | [3609128](#3609128)
| When you use vi with root or sudo, visual mode is enabled by default due to a missing vimrc configuration file. This makes it difficult to copy and paste into vi. In CL5.7.0, the default configuration now includes set mouse-=a
In addition, the CL5.7.0 default configuration for vi now disables modelines, which can be a security risk. | 5.5.0-5.6.0 | | | [3608014](#3608014)
| Software MAC learning might not work for a bridged VLAN subinterface on a bond (such as bond1.100) if you remove a VLAN subinterface completely from the configuration, then add it back with an identical configuration. To work around this issue, restart switchd. | 5.6.0 | | | [3603237](#3603237)
| If the secondary MLAG peer continuously reboots, you might experience momentary traffic loss. | 5.5.1-5.6.0 | | | [3600588](#3600588)
| You can't reset the root password by booting into Cumulus Linux single-user recovery mode. To work around this issue, follow the steps in https://docs.nvidia.com/networking-ethernet-software/cumulus-linux-56/Monitoring-and-Troubleshooting/Single-User-Mode-Password-Recovery/. | 5.6.0 | | -| [3599699](#3599699)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | +| [3599699](#3599699)
| Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf loopback ip address
command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the ping command to use a source address (such as an SVI address) with the ip vrf exec ping -I command. | 5.5.0-5.6.0 | | | [3597456](#3597456)
| NVUE does not allow you to use the reserved name lo in an interface name. | 5.5.1-5.6.0 | | | [3585467](#3585467)
| NVUE and ip link show traditional bridge VLAN subinterface counts incorrectly. The ingress (Rx) count increments correctly but the egress (Tx) count does not increment. This issues occurs because the hardware does not support transmit counters for a VLAN subinterface; therefore, no statistics from the hardware are updated. Statistics for software forwarded packets show correctly. | 5.0.0-5.6.0 | | | [3582826](#3582826)
| When you enable the FRR SNMP agent (agentx) and configure routing adjacencies with short timers (dead, keepalive, and hold time), the routing adjacencies might go down in certain scenarios; for example when you have frequent or concurrent client SNMP requests, you use custom SNMP MIB extensions, you poll OIDs with large responses, or during high CPU load. To work around this issue, you can increase the routing adjacency timers to accommodate SNMP processing. | 5.5.0-5.6.0 | | @@ -67,7 +67,7 @@ pdfhidden: True | [3368217](#3368217)
None | When daylight saving time changes, the MLAG initDelay timer resets and all MLAG bonds go down. | 4.4.4-4.4.5, 5.2.1-5.6.0 | | | [3362113](#3362113)
| If you restore an NVUE startup.yaml file after upgrade that includes breakout ports with QoS configuration or you run the nv config patch command to update a configuration with a yaml file that includes breakout ports with QoS configuration, the NVUE configuration fails to apply and subsequent attempts to run nv config apply fail with the following message:
cumulus@switch:~$ nv config applyInvalid config [rev_id: 11]
qos config is not supported on following invalid interface: swp1s0. Supported on swp and bond interface types
To work around this issue, run nv unset on the configured QoS settings, then apply the breakout port configuration before you configure QoS. Alternatively, you can remove the QoS configuration from the yaml file and patch it separately after applying the breakout configuration. | 5.4.0-5.6.0 | | | [3350027](#3350027)
| If you uninstall dynamic NAT rules and switchd restarts before all the dynamic NAT flows age out and are deleted, you might see dynamic flow deletion errors in switchd.log. These errors do not affect new dynamic NAT flows from new NAT rules. | 5.4.0-5.6.0 | | -| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown
In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. | 5.1.0-5.6.0 | | +| [3347677](#3347677)
| In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. | 5.1.0-5.6.0 | | | [3347538](#3347538)
| When connecting NVIDIA-to-NVIDIA in PAM4, you must enable auto-negotiation. | 5.4.0-5.6.0 | | | [3345054](#3345054)
| The NVUE nv show interface qos command takes a significant time to show output or times out. To work around this issue, use specific QoS commands. For example, to show congestion control information, run the nv show interface qos congestion-control command. | 5.4.0-5.6.0 | | | [3341214](#3341214)
| If you use the NVUE REST API to configure a local user with a hashed password, the user cannot log in and the /etc/nvue.d/startup.yaml file shows the password as plain text. | 5.4.0-5.6.0 | | @@ -81,7 +81,7 @@ pdfhidden: True | [3241567](#3241567)
| When you apply switch configuration for the first time on a freshly booted switch, you might see the error message Failed to start Hostname Service when you run the nv config apply command after setting the hostname with nv set system hostname. To work around this issue, run the nv config apply command a second time. | 5.3.0-5.6.0 | | | [3232091](#3232091)
| The NVUE nv unset interface link lanes command does not restore the port lane setting to the default value. To work around this issue, run the nv set interface link lanes command. | 5.4.0-5.6.0 | | | [3226506](#3226506)
| The l1-show eth0 command does not show port information and is not supported in this release. | 5.3.0-5.6.0 | | -| [3221628](#3221628)
| Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | +| [3221628](#3221628)
| Cumulus Linux VX images might include an incorrect entry at the end of /etc/apt/sources.list, which produces warnings when you run apt update. Remove this entry to avoid these warnings. | 5.2.0-5.6.0 | | | [3172504](#3172504)
| When you connect the NVIDIA SN4600C switch to a Spectrum 1 or Spectrum-3 switch with a 40GbE passive copper cable (Part Number: MC2210126-005) on edge ports 1-4 and 61-64, there is an Effective BER of 1E-12 in PHY. | 5.2.0-5.6.0 | | | [3147782](#3147782)
| You cannot use NVUE to configure an SNMP view to include a subtree beginning with a period. For example:
cumulus@switch:~$ nv set service snmp-server viewname cumulusOnly included .1.3.6.1.4.1.40310Error: GET /nvue_v1/service/snmp-server/viewname/cumulusOnly/included?pointers=%5B%22%2Fparameters%22%2C+%22%2Fpatch%2FrequestBody%2Fcontent%2Fapplication~1json%2Fschema%22%2C+%22%2Fpatch%2Fparameters%22%2C+%22%2Fpatch%2Fresponses%2F200%2Flinks%22%5D responded with 404 NOT FOUND
To work around this issue, reference the OID without the preceding period ( . ) in the command. | 5.3.0-5.6.0 | | | [3145869](#3145869)
| On a Spectrum-3 switch, the PTP offset in 10GbE changes between +-27. The average offset is around 7. | 5.2.0-5.6.0 | | diff --git a/content/cumulus-linux-56/rn.xml b/content/cumulus-linux-56/rn.xml index c0149bb4a6..fd9eff8f7b 100644 --- a/content/cumulus-linux-56/rn.xml +++ b/content/cumulus-linux-56/rn.xml @@ -36,14 +36,12 @@ <noformat> /usr/sbin/smond : : Path /run/hw-management/thermal/fan1_dir does not exist /usr/sbin/smond : : Path /run/hw-management/thermal/fan2_dir does not exist -</noformat> -{{smond}} has been modified to determine dynamically (at run-time) if the fan has the capability or not. - -To drop the messages before they get to the log, create a file, such as {{/etc/rsyslog.d/18-drop_fan_dir_msgs.conf}} with the following contents, then restart {{rsyslogd}} with the {{systemctl restart rsyslog}} command. +<noformat> +{{smond}} has been modified to determine dynamically (at run-time) if the fan has the capability. To drop the messages before they get to the log, create a file, such as {{/etc/rsyslog.d/18-drop_fan_dir_msgs.conf}} with the following contents, then restart {{rsyslogd}} with the {{systemctl restart rsyslog}} command. <noformat> # The lines below cause the offending message to be dropped from all logs :msg, ereregex, ".*Path /run/hw-management/thermal/fan[1-8]_dir does not exist" stop -</noformat> +<noformat> 5.6.0 @@ -136,7 +134,7 @@ These error messages do not affect how the switch functions; however the message 3610611 -Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the {{nv unset vrf <vrf> loopback ip address <address>}} command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. +Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf <vrf> loopback ip address command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. 5.5.0-5.6.0 @@ -168,7 +166,7 @@ In addition, the CL5.7.0 default configuration for {{vi}} now disables modelines 3599699 -Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the {{nv unset vrf <vrf> loopback ip address <address>}} command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. +Cumulus Linux assigns an IPv4 and IPv6 loopback address to a VRF interface by default. As a result, ping and route lookups for unique remote IP addresses on different VTEPs might not work if there is no source IP on the switch that belongs to the same subnet. To work around this issue, remove the loopback address on the VRF with the nv unset vrf <vrf> loopback ip address <address> command. Only remove the loopback address if you are not running NTP as NTP requires a loopback address to work. Alternatively, you can change the {{ping}} command to use a source address (such as an SVI address) with the {{ip vrf exec <VRF> ping <REMOTE_IP> -I <SVI_SRC_IP>}} command. 5.5.0-5.6.0 @@ -378,9 +376,7 @@ These errors do not affect new dynamic NAT flows from new NAT rules. 3347677 -In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. - -In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on secondary clag device on peerlink down trigger. This ensures smooth traffic flow and no convergence issue seen in system test bed with this fix. +In an MLAG configuration, when a link failure occurs on the peerlink or the peerlink shuts down, the switch in the secondary role attracts traffic to its local VTEP as it advertises the local VTEP IP address momentarily just before the VXLAN device is protodown. This traffic is dropped for a brief moment (between 5 and 10 seconds) because the MLAG bonds on the secondary switch are already protodown. 5.1.0-5.6.0 @@ -464,7 +460,7 @@ In a proposed fix in the MR !226, we are not flapping the IP on vxlan device on 3221628 -Cumulus Linux 5.2.0 and 5.2.1 VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. +Cumulus Linux VX images might include an incorrect entry at the end of {{/etc/apt/sources.list}}, which produces warnings when you run {{apt update}}. Remove this entry to avoid these warnings. 5.2.0-5.6.0