Notifications
You must be signed in to change notification settings - Fork 319
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
mpi-serial tests failing on Izumi with ctsm5.3.016 #2916
Labels
bug
something is working incorrectly
Milestone
Comments
Izumi was having problems, but these are now resolved. Closing. |
github-project-automation
bot
moved this from Todo
to Done
in LMWG: Near Term Priorities
Jan 9, 2025
Reopening because it's actually still happening. @ekluzek has a workaround here that I haven't tested. Apparently also it would work to manually call Note that we shouldn't close this issue without also closing the related expected failures. |
github-project-automation
bot
moved this from Done
to Todo
in LMWG: Near Term Priorities
Jan 15, 2025
samsrabin
added
next
this should get some attention in the next week or two. Normally each Thursday SE meeting.
and removed
closed: non-issue
Not really a problem
labels
Jan 15, 2025
wwieder
removed
the
next
this should get some attention in the next week or two. Normally each Thursday SE meeting.
label
Jan 16, 2025
samsrabin
added a commit
to samsrabin/CTSM
that referenced
this issue
Jan 16, 2025
Useful for redoing tests that failed due to ESCOMP#2916, after having replaced libraries/mpi-serial with a fresh copy.
Merged
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Brief summary of bug
This seems to still work with previous tags, and it actually worked with earlier versions of ctsm5.3.016, but is failing with the final testing so is a problem. It also fails robustly on rebuilding and trying new tests or deleting build directories.
General bug information
CTSM version you are using: ctsm5.3.016 ctsm5.3.015-28-ge2c1ae3d6
Does this bug cause significantly incorrect results in the model's science? no
Configurations affected: mpi-serial on Izumi
Details of bug
Details are here:
ESMCI/mpi-serial#31
The text was updated successfully, but these errors were encountered: