You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Cameras with the firmware 6.50 will eventually timeout the RTSP session at which point the camera responds with a 454 message instead of 200/ok. I have tried to extend the timeout on the camera or set it to 0. When the timeout is set to 0 or anonymous is allowed, the camera can't even get to its own VMD4 config page. Once the camera starts responding with 454 HA never trys to create a new session and the log is filled with more 454's after that point. Streaming still works but VMD4 events never make it to HA.
Also in my testing, if I did set the camera to one of these modes HA would never contact the camera again no matter how many times I restarted HA or the camera. My only workaround was to edit the device registry file and readd the camera. So that is a separate request to allow us to remove cameras without editing the device registry file.
2020-03-26 00:26:49 DEBUG (MainThread) [axis.rtsp] Received data ['RTSP/1.0 200 OK', 'CSeq: 4', 'Public: OPTIONS, DESCRIBE, GET_PARAMETER, PAUSE, PLAY, SETUP, SET_PARAMETER, TEARDOWN', 'Server: GStreamer RTS
P server', 'Session: rkWgPZCGKBUj7MkC; timeout=60', 'Date: Wed, 25 Mar 2020 23:26:51 GMT', ''] from 192.168.1.41
2020-03-26 00:26:49 DEBUG (MainThread) [axis.rtsp] RTSP session (192.168.1.41) state playing
2020-03-26 00:26:49 DEBUG (MainThread) [axis.rtsp] RTSP session (192.168.1.41) state playing
2020-03-26 00:26:49 DEBUG (MainThread) [axis.rtsp] RTSP session (192.168.1.41) state playing
2020-03-26 00:27:09 DEBUG (MainThread) [axis.rtsp] OPTIONS rtsp://192.168.1.42/axis-media/media.amp?video=0&audio=0&event=on RTSP/1.0
CSeq: 4
User-Agent: HASS Axis
Session: N7_Xkk8ES1PglRDl
2020-03-26 00:27:51 DEBUG (MainThread) [axis.rtsp] Received data ['RTSP/1.0 454 Session Not Found', 'CSeq: 4', 'Server: GStreamer RTSP server', 'Date: Wed, 25 Mar 2020 23:27:54 GMT', ''] from 192.168.1.41
2020-03-26 00:27:51 DEBUG (MainThread) [axis.rtsp] 192.168.1.41 RTSP 454 Session
2020-03-26 00:27:51 DEBUG (MainThread) [axis.rtsp] RTSP session (192.168.1.41) state playing
2020-03-26 00:27:51 DEBUG (MainThread) [axis.rtsp] RTSP session (192.168.1.41) state playing
2020-03-26 00:28:04 DEBUG (MainThread) [axis.rtsp] OPTIONS rtsp://192.168.1.42/axis-media/media.amp?video=0&audio=0&event=on RTSP/1.0
CSeq: 4
User-Agent: HASS Axis
Session: N7_Xkk8ES1PglRDl
The text was updated successfully, but these errors were encountered:
Cameras with the firmware 6.50 will eventually timeout the RTSP session at which point the camera responds with a 454 message instead of 200/ok. I have tried to extend the timeout on the camera or set it to 0. When the timeout is set to 0 or anonymous is allowed, the camera can't even get to its own VMD4 config page. Once the camera starts responding with 454 HA never trys to create a new session and the log is filled with more 454's after that point. Streaming still works but VMD4 events never make it to HA.
Also in my testing, if I did set the camera to one of these modes HA would never contact the camera again no matter how many times I restarted HA or the camera. My only workaround was to edit the device registry file and readd the camera. So that is a separate request to allow us to remove cameras without editing the device registry file.
The text was updated successfully, but these errors were encountered: