See usage instructions for more options and info.
In case of using parametric equalizer, apply preamp of -5.2dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -5.2 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 23 Hz | 0.51 | 3.8 dB |
Peaking | 209 Hz | 0.91 | -2.8 dB |
Peaking | 3163 Hz | 2.39 | 3.0 dB |
Peaking | 4781 Hz | 2.21 | 3.6 dB |
Peaking | 19249 Hz | 0.44 | 5.0 dB |
Peaking | 882 Hz | 2.03 | 1.7 dB |
Peaking | 1503 Hz | 2.53 | -1.3 dB |
Peaking | 5917 Hz | 6.05 | 3.1 dB |
Peaking | 6601 Hz | 3.1 | -1.5 dB |
Peaking | 7453 Hz | 4.62 | -1.3 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -5.1dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | 4.2 dB |
Peaking | 62 Hz | 1.41 | 0.8 dB |
Peaking | 125 Hz | 1.41 | -1.1 dB |
Peaking | 250 Hz | 1.41 | -2.7 dB |
Peaking | 500 Hz | 1.41 | -0.1 dB |
Peaking | 1000 Hz | 1.41 | 1.0 dB |
Peaking | 2000 Hz | 1.41 | -0.9 dB |
Peaking | 4000 Hz | 1.41 | 5.1 dB |
Peaking | 8000 Hz | 1.41 | -0.6 dB |
Peaking | 16000 Hz | 1.41 | 4.7 dB |