See usage instructions for more options and info.
In case of using parametric equalizer, apply preamp of -4.1dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -4.0 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 19 Hz | 0.09 | -6.7 dB |
Peaking | 788 Hz | 1.16 | 2.5 dB |
Peaking | 2180 Hz | 2.74 | 2.0 dB |
Peaking | 5559 Hz | 1.71 | 2.0 dB |
Peaking | 8986 Hz | 2.19 | 3.4 dB |
Peaking | 17 Hz | 1.22 | -0.4 dB |
Peaking | 11922 Hz | 1.32 | 2.3 dB |
Peaking | 19834 Hz | 0.4 | -9.2 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -4.2dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | -7.3 dB |
Peaking | 62 Hz | 1.41 | -4.3 dB |
Peaking | 125 Hz | 1.41 | -3.7 dB |
Peaking | 250 Hz | 1.41 | -2.4 dB |
Peaking | 500 Hz | 1.41 | 0.8 dB |
Peaking | 1000 Hz | 1.41 | 1.6 dB |
Peaking | 2000 Hz | 1.41 | 1.2 dB |
Peaking | 4000 Hz | 1.41 | 0.5 dB |
Peaking | 8000 Hz | 1.41 | 4.2 dB |
Peaking | 16000 Hz | 1.41 | -5.3 dB |