In case of using parametric equalizer, apply preamp of -6.6dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -6.4 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 27 Hz | 0.52 | 6.2 dB |
Peaking | 198 Hz | 1.05 | 6.3 dB |
Peaking | 364 Hz | 1.14 | -5.4 dB |
Peaking | 6190 Hz | 1.32 | 11.0 dB |
Peaking | 6697 Hz | 0.12 | -4.8 dB |
Peaking | 1769 Hz | 1.09 | -2.1 dB |
Peaking | 2380 Hz | 4.86 | 3.7 dB |
Peaking | 3563 Hz | 6.2 | -2.5 dB |
Peaking | 7608 Hz | 0.16 | 1.8 dB |
Peaking | 10913 Hz | 0.62 | -2.6 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -7.6dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | 7.1 dB |
Peaking | 62 Hz | 1.41 | 1.3 dB |
Peaking | 125 Hz | 1.41 | 4.0 dB |
Peaking | 250 Hz | 1.41 | 2.0 dB |
Peaking | 500 Hz | 1.41 | -4.5 dB |
Peaking | 1000 Hz | 1.41 | -2.0 dB |
Peaking | 2000 Hz | 1.41 | -3.4 dB |
Peaking | 4000 Hz | 1.41 | 1.3 dB |
Peaking | 8000 Hz | 1.41 | 2.5 dB |
Peaking | 16000 Hz | 1.41 | -6.0 dB |