Not working on a (test) DS214play DSM 7.1.1-42962 Update 6 #11

Open
riogrande75 opened this issue Nov 20, 2024 · 4 comments
Open

Not working on a (test) DS214play DSM 7.1.1-42962 Update 6 #11

riogrande75 opened this issue Nov 20, 2024 · 4 comments

Comments

@riogrande75
Copy link

riogrande75 commented Nov 20, 2024

After applying the patch (X86_64, 9.2.0_11289) surveillance station starts, unfortunately, it cannot be accessed.
grafik

Executing the script on the cli (via ssh) manully does not show any error.
Any idea what could be the problem? What logs could be helpful?

@ohyeah521
Copy link
Owner

It is possible that your patch does not take effect. Please remove the patch and try reinstalling it.

@riogrande75
Copy link
Author

I tried that many times.
It even looks like ss package is running after script installation (see attached logs), but I cannot log in anymore.
synoSSlic.txt
Any idea, where to look at? How can I verify that the script installation was really succesful?

@ohyeah521
Copy link
Owner

ohyeah521 commented Nov 21, 2024

I found that your dsm is not an x86 architecture, but an i686 architecture. There is no crack patch for this architecture.

@domi1968
Copy link

domi1968 commented Nov 23, 2024

bonjour serrait il possible d avoir un patch patch pour ds214+ MARVELL Armada XP MV78230 merci