same issue here when trying to connect two TS-SH controllers, is there any idea to solve? |
I am having a similar issue as well. I need to connect to multiple devices and send/receive implicit messages. If I change OriginatorUDPPort to anything other than 2222, T_O_IOData is all zeroes. Is there an example showing how to manage multiple device connections? |
Some additional info: |
Originally posted by @ralftar in #16 (comment):
I have a feeling that this repository is stalled..? Being MIT licensed, some one can of course create a fork, and continue the work. But it requires long time commitment and resources. Also, I think it would be best if @rossmann-engineering, the original author, is still connected to the maintenance in some form. |
Did any solution to this ever come to light or is the issue still present? I am having the same problem with two AZ-KEP drives |
I am having the same problem with two Keyence Camra IV2 and CVX. They are able to communicate simultaneously in explicit mode. But, not in Implicit mode. When I change any .OriginatorUDPPort property from 2222 default, communication stops. |
Based on the source code, I suspect the target is not aware that it needs to communicate to a port other than the default. |
bool O_T_OwnerRedundant Only for Implicit Messaging True if Multiple Implicit connections are allowed (Standard: TRUE) Both properties are True but do not work ... |
I had the same issue and it looks like the answer is here: https://github.com/campbell-git/EEIP.NET/tree/testing Since UDP only allows one port per connection, the above repository is a fork from the original, but has an I managed to talk to 3 VFDs using Ethernet/IP using that library. |
First of all, congratulations on this library, it is very good!
The thing is, I can't connect to two devices
FEN20s at the same time from a PC.
Error:
Only one usage of each socket address (protocol / network address / port) is normally permitted.
Is there any solution for this?
Regards!