Climate configuration

anotherjulien edited this page Feb 17, 2023 · 1 revision

Climate entities are developed for WHO 4

There are 3 distinct ways to configure this part depending on your setup.

99 zones central unit

In a 99 zones setup, the central unit needs to have the address #0, and all subordinate zones have their own number with and are NOT standalone.
zone is the zone (equivalent to where)
heat is an optional boolean defaulting to True you can set if your installation supports heating
cool is an optional boolean defaulting to False you can set if your installation supports cooling
standalone is an optional boolean defaulting to False, you can either ignore it or set it manually to False when you have a 99 zones setup

Configuration example

  climate:
    central_unit:
      zone: '#0'
      name: Central unit
      heat: True
      cool: False
      standalone: False
      manufacturer: BTicino
      model: 3550
    zone_1:
      zone: '1'
      name: Living room
      heat: True
      cool: False
      standalone: False
      manufacturer: BTicino
      model: F430/4

4 zones central unit

When you use a 4 zones central unit, the central unit itself acts as a separate zone, so it has a zone number configured; all subordinate zones are standalone.
zone is the zone (equivalent to where)
heat is an optional boolean defaulting to True you can set if your installation supports heating
cool is an optional boolean defaulting to False you can set if your installation supports cooling
centralis an optional boolean defaulting toFalse that you need to set to True only for the zone that acts as the central unit in your 4 zones setup
standalone is an optional boolean defaulting to False that you need to set to True for all subordinate zones in a 4 zones setup

Configuration example

  climate:
    central_unit:
      zone: '1'
      name: Central unit Living room
      heat: True
      cool: False
      central: True
      standalone: False
      manufacturer: BTicino
      model: HC4695
    zone_2:
      zone: '2'
      name: Bedroom
      heat: True
      cool: False
      standalone: True
      manufacturer: BTicino
      model: F430/4

No central unit

With no central unit, all zones are set as standalone.
zone is the zone (equivalent to where)
heat is an optional boolean defaulting to True you can set if your installation supports heating
cool is an optional boolean defaulting to False you can set if your installation supports cooling
standalone is an optional boolean defaulting to False that you need to set to True for all zones when you don't have any central unit

Configuration example

  climate:
    zone_1:
      zone: '1'
      name: Living room
      heat: True
      cool: False
      standalone: True
      manufacturer: BTicino
      model: H4691
    zone_2:
      zone: '2'
      name: Bedroom
      heat: True
      cool: False
      standalone: True
      manufacturer: BTicino
      model: H4691