Add Danfoss manufacturer specific commands to general.xml (#7963)
Browse files Browse the repository at this point in the history
  • Loading branch information
SwoopX authored Nov 8, 2024
1 parent c5cac4c commit e2b5a08
Showing 1 changed file with 31 additions and 0 deletions.
31 changes: 31 additions & 0 deletions general.xml
Original file line number Diff line number Diff line change
Expand Up @@ -2823,6 +2823,37 @@ Note: It does not clear or delete previous weekly schedule programming configura
</command>
<command id="0x03" dir="recv" name="Clear Weekly Schedule" required="o"></command>
<command id="0x04" dir="recv" name="Get Relay Status Log" required="o"></command>
<!-- Danfoss manufacturer specific -->
<command id="0x40" dir="recv" name="Set Heating Setpoint" required="o" mfcode="0x1246">
<description>Set immediately:
The actuator will make a large movement to minimize reaction time.

Mimic Occupied Heating Setpoint Behavior:
The behavior will be the same as setting the attribute "Occupied Heating Setpoint" to the same value.

Preserve Displayed Setpoint:
Displayed setpoint is not affected, but regulated setpoint will change. Can be used for Forecast functionality.</description>
<payload>
<attribute id="0x0000" type="enum8" name="Setpoint Type" required="m">
<value name="Set immediately" value="0"/>
<value name="Mimic Occupied Heating Setpoint Behavior" value="1"/>
<value name="Preserve Displayed Setpoint" value="2"/>
</attribute>
<attribute id="0x0001" type="u16" name="Heating Setpoint" required="m"/>
</payload>
</command>
<command id="0x41" dir="recv" name="Danfoss Test Command" required="o" mfcode="0x1246"></command>
<command id="0x42" dir="recv" name="Preheat" required="o" mfcode="0x1246">
<description>Request eTRV to enter pre-heat if in schedule mode and if other eTRV in same room has triggeed pre-heat.</description>
<payload>
<attribute id="0x0000" type="enum8" name="Type" required="m">
<value name="Force Preheat" value="0"></value>
</attribute>
<attribute id="0x0001" type="u32" name="Timestamp" required="m">
<description>Timestamp received from other eTRV in the same room that went into preheat.</description>
</attribute>
</payload>
</command>
</server>
<client>
<command id="0x00" dir="recv" name="Get Weekly Schedule Response" required="o">